PFA Products
Precision meets purity
Why Savillex PFA bottles are trusted across critical industries
Savillex fluoropolymer PFA bottles deliver unmatched chemical purity, durability, and performance for demanding applications. Whether you're working in life sciences, geochemistry, aerospace, environmental testing, or semiconductors, these bottles protect your samples and your results.
The fluoropolymer difference
PFA (perfluoroalkoxy) bottles are high-performance fluoropolymer containers designed for ultra-pure sample and drug product storage and transport, ultra-trace analysis, and chemical handling in cleanroom, lab, and field enviroments. They resist aggressive chemicals, tolerate extreme temperatures, and prevent contamination. Savillex PFA bottles offer superior chemical inertness, low trace metal content, and consistent quality trusted by leading labs and manufacturers worldwide.
Why Savillex bottles outperform the competition
Ultra-Pure Materials for Critical Applications
Savillex PFA bottles are made from high-purity fluoropolymers, offering near-zero extractables - ideal for trace metals, organics, and sensitive biologicals.
Extreme Temperature Resistance
Savillex PFA bottles withstand –200°C to +260°C, making them suitable for cryogenic storage, autoclaving, and high-temp applications.
Read our application notes:
Flash freezing in fluoropolymer bottles
Freeze cycle testing on Purillex Fluoropolymer Bottles
Superior Chemical Compatibility
PFA resists strong acids, bases, solvents, and oxidizers—no degradation, no compromise.
Check chemical compatibility with our chemical compatibility guide.
Leakproof Assurance
Savillex PFA bottles feature precision-machined closures for airtight, leakproof performance—even under pressure or temperature extremes.
Read our technical note: Integrity testing of Purillex containers
Available sizes and customization
Savillex PFA bottles come in a range of volumes from 30 mL to 1 L. Custom sizes, labeling, and packaging options are available to meet your workflow needs.
Trusted by leading labs and manufacturers
Savillex has over 40 years of experience in fluoropolymer molding. Our PFA bottles are used by top-tier research institutions, government labs, and Fortune 500 companies.
Ready to upgrade your sample integrity?
Explore the full line of Savillex PFA bottles and request a quote today. Protect your data, your samples, and your reputation with the industry’s most trusted PFA solution. [Contact us] or [Request a sample] to see the difference.
General and Technical Notes
-
2 mL PFA Vial, Conical Interior
- Comparable to Agilent ICP-MS part number G3160-65315 but in PFA (2 mL polyethylene vial for I-AS tray type D)
- Alternative to ESI part number V-14-0312CG-X (2 mL PFA vial)
- Slightly conical interior base
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
Material: PFAVolume: 2 mL$7.68
-
3 mL Standard Octagonal Body Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Square body allows for secure, tight fit using accompanying closure and wrench set
- Flat interior allows for large surface area for contents
Material: PFAVolume: 3 mL$10.91
-
3 mL Standard Octagonal Body Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat sides on body allows for secure, tight fit using accompanying closure and wrench set
- Rounded interior allows for easy removal of contents
Material: PFAVolume: 3 mL$10.19
-
3 mL Standard Octagonal Body Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Square body allows for secure, tight fit using accompanying closure and wrench set
- Conical interior maximizes content retrieval
Material: PFAVolume: 3 mL$12.24
-
4 mL PFA Vial, Rounded Interior
- Comparable to Agilent ICP-MS part number G3160-65303 but in PFA (6 mL polypropylene vial for I-AS tray type A and E)
- Same product as Cetac ASX110/112 part number SP6332 (4 mL PFA vial)
- Fits other autosamplers used in ICP-MS and GFAAS
- Rounded interior base
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
Material: PFAVolume: 4 mL$21.03
-
4 mL PFA Vial, Conical Interior
- Alternative to ESI part number V-14-0314CG-X (4 mL PFA vial)
- Slightly conical interior base
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Note: For an alternative to comparable Agilent ICP-MS part number G3160-65303 (6 mL polypropylene vial for I-AS tray type A and E), choose part number 200-004-13 instead
Material: PFAVolume: 4 mL$15.31
-
5 mL Standard Vial, Conical Interior, Fin Legs
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Steep conical profile maximizes content retrieval
- Fin-Legs provide stability
Material: PFAVolume: 5 mL$14.20
-
6 mL Standard Octagonal Body Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hotplate heating
- Flat sides on body allows for secure, tight fit using accompanying closure and wrench set
- Round interior allows for easy removal of contents
Material: PFAVolume: 6 mL$18.75
-
7 mL Standard Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat interior allows for large surface area for contents
Material: PFAVolume: 7 mL$13.02
-
7 mL Standard Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Round interior allows for easy removal of contents
Material: PFAVolume: 7 mL$12.92
-
7 mL Standard Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Conical interior maximizes content retrieval
Material: PFAVolume: 7 mL$14.13
-
10 mL PFA Vial – ASX Autosampler compatible
- Same product as Cetac ASX110/112 part number SP6334 (10 mL PFA vial)
- Fits other autosamplers used in ICP-MS and GFAAS
- Rounded interior base
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
Material: PFAVolume: 10 mL$24.49
-
13 mL PFA Vial, Flat Interior
- Comparable to Agilent ICP-MS part number G3160-65304 but in PFA (18 mL polypropylene vial for I-AS tray type B, D and E)
- Fits other autosamplers used in ICP-MS and GFAAS
- Flat interior base
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
Material: PFAVolume: 1.3 mL$26.88
-
15 mL Standard Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500 °F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat interior allows for large surface area for contents
Material: PFAVolume: 15 mL$22.87
-
15 mL Standard Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500 °F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Round interior allows for easy removal of contents
Material: PFAVolume: 15 mL$22.76
-
15 mL Standard Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Conical interior maximizes content retrieval
Material: PFAVolume: 15 mL$25.71
-
20 mL PFA Vial – ASX Autosampler compatible
- Same product as Cetac ASX110/112 part number SP6333 (20 mL PFA vial)
- Fits other autosamplers used in ICP-MS and GFAAS
- Shallow tapered interior base
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
Material: PFAVolume: 20 mL$28.82
-
22 mL Standard Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat interior allows for large surface area for contents
Material: PFAVolume: 22 mL$27.38
-
22 mL Standard Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Round interior allows for easy removal of contents
Material: PFAVolume: 22 mL$26.60
-
22 ml Standard Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Conical interior maximizes content retrieval
Material: PFAVolume: 22 mL$29.66
-
30 mL Standard Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat interior allows for large surface area for contents
Material: PFAVolume: 30 mL$37.07
-
30 mL PFA Vial – ASX Autosampler compatible
- Same product as Cetac ASX110/112 part number SP6335 (30 mL PFA vial)
- Fits other autosamplers used in ICP-MS and GFAAS
- Shallow tapered interior base
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
Material: PFAVolume: 30 mL$44.91
-
30 mL Standard Vial, Rounded Interior
- Flat surface on bottom of vial ideal for hot plate heating
- Round interior allows for easy removal of contents
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
Material: PFAVolume: 30 mL$32.78
-
30 mL Standard Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Conical interior maximizes content retrieval
Material: PFAVolume: 30 mL$33.17
-
60 mL Standard Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat interior allows for large surface area for contents
- Referenced in EPA Method 1630
Material: PFAVolume: 60 mL$63.95
-
60 mL Standard Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Round interior allows for easy removal of contents
- Referenced in EPA Method 1630
Material: PFAVolume: 60 mL$71.18
-
60 mL Standard Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Conical interior maximizes content retrieval
- Referenced in EPA Method 1630
Material: PFAVolume: 60 mL$76.63
-
200 µL Forensic Vial
- Can be used for numerous storage methods: LN2 liquid phase (‑196°C), LN2 Vapor Phase (‑150°C), Ultra-low (‑80°C) or standard freezer (4°C)
- Will fit most standard benchtop microcentrifuge units
- Low coefficient of friction of PFA provides higher sample recovery of low concentration samples than standard storage vials
- PFA offers superior purity, storage and stability over other plastics
- See our microcentrifuge tubes for more storage options
Material: PFA$14.08
-
500 µL Forensic Vial
- Can be used for numerous storage methods: LN2 liquid phase (‑196°C), LN2 Vapor Phase (‑150°C), Ultra-low (‑80°C) or standard freezer (4°C)
- Will fit most standard benchtop microcentrifuge units
- Low coefficient of friction of PFA provides higher sample recovery of low concentration samples than standard storage vials
- PFA offers superior purity, storage and stability over other plastics
- See our microcentrifuge tubes for more storage options
Material: PFA$13.02
-
200 µL PFA Vial, Conical Interior, Threaded Opening
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Standard 12x32 autosampler vial
Material: PFAVolume: 0.2 mL$16.02
-
200 µL PFA Vial, Conical Interior, Crimp Top Opening
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Standard 12x32 autosampler vial
- Vial accommodates standard 11mm crimp top closure
Material: PFAVolume: 0.2 mL$14.64
-
200 µL Specialty Vial, Ludwig Style
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Ideal for multiple digestions in pressure bomb apparatus
- Round interior allows for easy removal of contents
Material: PFAVolume: 0.2 mL$14.75
-
350 µL Specialty Vial, Parrish Style
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Ideal for multiple digestions in pressure bomb apparatus
- Thicker wall allows for higher pressure applications
- Round interior allows for easy removal of contents
Material: PFAVolume: 0.35 mL$20.20
-
500 µL PFA Vial, Straight Interior, Threaded Opening
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Standard 12x32 autosampler vial
Material: PFAVolume: 0.5 mL$11.52
-
500 µL PFA Vial, Straight Interior, Crimp Top Opening
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Standard 12x32 autosampler vial
- Vial accommodates standard 11 mm crimp top closure
Material: PFAVolume: 0.5 mL$13.47
-
500 µL Microcentrifuge Vial, 8 mm Snap-on Opening
- Conical interior base
- Will fit most standard microcentrifuge models
- 8 mm Snap-on Opening
- RCF up to 10,000 g
- Alternative to Cetac ASX110/112 part number SP5477 (0.5 mL PFA vial)
- Fits other autosamplers used in ICP-MS and GFAAS
- Can be used as a tip cover for PFA wash bottle part #700-500
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
Material: PFA$9.96