Clean Sample Prep
Clean Sample Prep
-
3 mL Standard Octagonal Body Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Square body allows for secure, tight fit using accompanying closure and wrench set
- Flat interior allows for large surface area for contents
Material: PFAVolume: 3 mL$11.83
-
3 mL Standard Octagonal Body Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat sides on body allows for secure, tight fit using accompanying closure and wrench set
- Rounded interior allows for easy removal of contents
Material: PFAVolume: 3 mL$11.09
-
3 mL Standard Octagonal Body Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Square body allows for secure, tight fit using accompanying closure and wrench set
- Conical interior maximizes content retrieval
- NOTE: product image appears to show a flat interior because conical inner shape cant be seen. Refer to Specifications tab > Standard Vial Web Drawing for actual interior shape.
Material: PFAVolume: 3 mL$12.98
-
5 mL Standard Vial, Conical Interior, Fin Legs
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Steep conical profile maximizes content retrieval
- Fin-Legs provide stability
Material: PFAVolume: 5 mL$16.54
-
6 mL Standard Octagonal Body Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hotplate heating
- Flat sides on body allows for secure, tight fit using accompanying closure and wrench set
- Round interior allows for easy removal of contents
Material: PFAVolume: 6 mL$21.78
-
7 mL Standard Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat interior allows for large surface area for contents
Material: PFAVolume: 7 mL$13.80
-
7 mL Standard Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Round interior allows for easy removal of contents
Material: PFAVolume: 7 mL$13.69
-
7 mL Standard Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Conical interior maximizes content retrieval
Material: PFAVolume: 7 mL$16.27
-
15 mL Standard Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500 °F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat interior allows for large surface area for contents
Material: PFAVolume: 15 mL$24.24
-
15 mL Standard Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500 °F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Round interior allows for easy removal of contents
Material: PFAVolume: 15 mL$24.54
-
15 mL Standard Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Conical interior maximizes content retrieval
Material: PFAVolume: 15 mL$27.26
-
22 mL Standard Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat interior allows for large surface area for contents
Material: PFAVolume: 22 mL$29.76
-
22 mL Standard Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Round interior allows for easy removal of contents
Material: PFAVolume: 22 mL$30.66
-
22 ml Standard Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Conical interior maximizes content retrieval
Material: PFAVolume: 22 mL$31.44
-
30 mL Standard Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat interior allows for large surface area for contents
Material: PFAVolume: 30 mL$42.57
-
30 mL Standard Vial, Rounded Interior
- Flat surface on bottom of vial ideal for hot plate heating
- Round interior allows for easy removal of contents
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
Material: PFAVolume: 30 mL$34.75
-
30 mL Standard Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Conical interior maximizes content retrieval
Material: PFAVolume: 30 mL$38.22
-
60 mL Standard Vial, Flat Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Flat interior allows for large surface area for contents
- Referenced in EPA Method 1630
Material: PFAVolume: 60 mL$74.26
-
60 mL Standard Vial, Rounded Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Round interior allows for easy removal of contents
- Referenced in EPA Method 1630
Material: PFAVolume: 60 mL$81.63
-
60 mL Standard Vial, Conical Interior
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat surface on bottom of vial ideal for hot plate heating
- Conical interior maximizes content retrieval
- Referenced in EPA Method 1630
Material: PFAVolume: 60 mL$88.23
-
200 µL Specialty Vial, Ludwig Style
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Ideal for multiple digestions in pressure bomb apparatus
- Round interior allows for easy removal of contents
Material: PFAVolume: 0.2 mL$16.14
-
350 µL Specialty Vial, Parrish Style
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Ideal for multiple digestions in pressure bomb apparatus
- Thicker wall allows for higher pressure applications
- Round interior allows for easy removal of contents
Material: PFAVolume: 0.35 mL$21.96
-
4 mL Block Digestion Tube, Rounded Interior, Threaded Top
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for block digestion units
- Compatible with all acids
- Threaded top for long term storage
Volume: 4 mL$34.64
-
10 mL Block Digestion Tube, Conical Interior, Threaded Top
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for block digestion units
- Compatible with all acids
- Threaded top for long term storage
Volume: 10 mL$65.52
-
17 mL Block Digestion Tube, Rounded Interior, Threaded Top
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for block digestion units
- Compatible with all acids
- Threaded top for long term storage
Volume: 17 mL$69.06
-
25 mL Block Digestion Tube, Conical Interior, Threaded Top
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for block digestion units
- Compatible with all acids
- Threaded top for long term storage
Volume: 25 mL$57.02
-
50 mL PFA Block Digestion Tube with Closure
- Designed for block digestion units
- Thin walled for maximum heat transfer and good visibility of contents
- 50 mL graduation mark to Class A specifications
- Includes a threaded polypropylene closure
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
Material: PFAVolume: 50 mL$78.13
-
75 mL Block Digestion Tube, Flat Interior, Open Top
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for block digestion units
- Compatible with all acids
Volume: 75 mL$99.75
-
2 mL Microcolumn, 1.5 mm ID x 3.2 mm OD x 15 cm Capillary
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for ion exchange chromatography
- Frits are not included and must be purchased separately
Volume: 2 mL$189.18
-
2 mL Microcolumn, 2.4 mm ID x 4.0 mm OD x 15 cm Capillary
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for ion exchange chromatography
- Frits are not included and must be purchased separately
Volume: 2 mL$189.03
-
5 mL Microcolumn, 3.2 mm ID x 4.7 mm OD x 20 cm Capillary
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for ion exchange chromatography
- Frits are not included and must be purchased separately
Volume: 5 mL$196.49
-
6 mL Microcolumn, 2.4 mm ID x 4.0 mm OD x 15 cm Capillary
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for ion exchange chromatography
- Frits are not included and must be purchased separately
Volume: 6 mL$215.92
-
15 mL Microcolumn, 4.0 mm ID x 6.3 mm OD x 20 cm Capillary
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for ion exchange chromatography
- Frits are not included and must be purchased separately
Volume: 15 mL$200.97
-
30 mL Microcolumn, 6.4 mm ID x 9.6 mm OD x 25 cm Capillary
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Designed for ion exchange chromatography
- Frits are not included and must be purchased separately
Volume: 30 mL$225.73
-
60 mL Digestion Vessel, Flat Interior, Flat Exterior, Buttress Threaded Top
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Flat exterior for hot plate heating and digestion
- Wrench set recommended for tightening
- IMPORTANT! Savillex digestion vessels are not designed to be used in microwave digestions systems. Savillex does not support their use in such systems due to the safety risk arising from the rapid increases in pressure and temperature that can occur.
Volume: 60 mL$65.71
-
60 mL Digestion Vessel, Conical Interior, Cored Exterior, Buttress Threaded Top
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Conical interior to aide in sample removal
- Wrench set recommended for tightening
- IMPORTANT! Savillex digestion vessels are not designed to be used in microwave digestions systems. Savillex does not support their use in such systems due to the safety risk arising from the rapid increases in pressure and temperature that can occur.
Volume: 60 mL$66.96