Environmental
Trusted by Environmental Professionals Worldwide
At Savillex, we understand the critical role that accurate, contamination-free sampling and analysis plays in protecting our planet. For over four decades, environmental scientists, regulatory agencies, and analytical labs have relied on our high-purity fluoropolymer products to support their mission of monitoring and preserving air, water, and soil quality. Whether you're conducting trace metal analysis, collecting field samples, or performing cleanroom operations, Savillex delivers the precision, durability, and chemical resistance your work demands.
Why Environmental Experts Choose Savillex
✅ Ultra-Clean Sample Integrity
Our PFA and FEP containers are engineered to eliminate contamination risks, ensuring the integrity of even the most sensitive samples. With unmatched chemical inertness and ultra-low trace metal background levels, Savillex products are ideal for ICP-MS, EPA 200.8, and other ultra-trace analytical methods.
✅ Field-Tested Durability
Environmental sampling often happens in rugged, remote conditions. Savillex containers are built to withstand harsh environments—from arctic tundra to industrial sites—without compromising sample quality.
✅ Compliance and Confidence
Our products meet stringent environmental testing standards and are trusted by leading organizations including the US EPA, USGS, and global environmental labs. When accuracy and compliance matter, Savillex delivers.
Applications in the Environmental Sector
Water Quality Monitoring
Safely collect and store water samples for trace metal and organic contaminant analysis.
Air and Soil Sampling
Use Savillex containers for clean sample collection in air particulate and soil testing programs.
Cleanroom and Lab Operations
Maintain contamination-free environments with our PFA labware, ideal for high-purity workflows.
Environmental Research & Remediation
Support long-term studies and remediation efforts with reliable containment solutions.
Featured Products for Environmental Use
PFA Bottles & Vials – Ideal for trace metal analysis and long-term sample storage Savillex Purge & Trap Systems – Designed for VOC analysis in water and soil Custom Fluoropolymer Solutions – Tailored to meet unique sampling and containment needs
Partnering for a Cleaner Future
At Savillex, we don’t just manufacture labware—we partner with environmental professionals to advance science and sustainability. Our team of experts is ready to help you select the right products, customize solutions, and ensure your sampling and analysis workflows are optimized for success. Let’s work together to protect the environment—one sample at a time.
Ready to Elevate Your Environmental Testing?
Explore our full product line or contact our team to discuss your specific needs. 📞
-
7 mL Purillex PFA Vial
7 mL Vial Designed for Life Sciences Applications
- Ideal for stability testing, final drug product sample storage, vaccine seed stock preparation, viral vector storage, and storage of LNP formulations
- Produced using the same resin manufacturer and grade as our Purillex® Life Sciences bottles
- Includes PFA closure
- Includes full lot certification
- Available sterilized (autoclaved) upon request
Material: PFA$27.84
-
7 mL Purillex PFA Vials, Rack Refill, 50 Vials/Case
- Ideal for stability testing, final drug product sample storage, vaccine seed stock preparation, viral vector storage, and storage of LNP formulations
- Produced using the same resin manufacturer and grade as our Purillex® Life Sciences bottles
- Includes PFA closure
- Includes full lot certification
- 50 vials with closure in a single bag
Material: PFA$1,252.63
-
15 mL Purillex PFA Vial
15 mL Vial Designed for Life Sciences Applications
- Ideal for stability testing, final drug product sample storage, vaccine seed stock preparation, viral vector storage, and storage of LNP formulations
- Produced using the same resin manufacturer and grade as our Purillex® Life Sciences bottles
- Includes PFA closure
- Includes full lot certification
- Available sterilized (autoclaved) upon request
Material: PFA$45.93
-
15 mL Purillex PFA Vials, Rack Refill, 50 Vials/Case
- Ideal for stability testing, final drug product sample storage, vaccine seed stock preparation, viral vector storage, and storage of LNP formulations
- Produced using the same resin manufacturer and grade as our Purillex® Life Sciences bottles
- Includes PFA closure
- Includes full lot certification
- 50 vials with closure in a single bag
Material: PFA$2,067.01
-
7 mL Purillex PFA Vials, Racked, 10 Racks/Case
- Ideal for stability testing, final drug product sample storage, vaccine seed stock preparation, viral vector storage, and storage of LNP formulations
- Produced using the same resin manufacturer and grade as our Purillex® Life Sciences bottles
- Includes full lot certification
- 10 Vials/Rack, 10 Racks/Case, 100 Vials/Case
Material: PFA$2,941.66
-
15 mL Purillex PFA Vials, Racked, 10 Racks/Case
- Ideal for stability testing, final drug product sample storage, vaccine seed stock preparation, viral vector storage, and storage of LNP formulations
- Produced using the same resin manufacturer and grade as our Purillex® Life Sciences bottles
- Includes full lot certification
- 10 Vials/Rack, 10 Racks/Case, 100 Vials/Case
Material: PFA$4,759.08
-
47 mm Single Stage Filter Assembly, 1/4" x 1/4", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$186.86
-
50 mm Single Stage Filter Assembly, 1/4" x 1/4", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
- Suitable as particulate filter for EPA method 16A
Material: PFA$223.01
-
47 mm Single Stage Filter Assembly, 1/4" MNPT x 1/4" MNPT, PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- TefzelÒ clamp nut for higher pressure applications
- TefzelÒ service temperature range (300/148)
- Recommend wrench set for assembly
Material: PFA$186.99
-
50 mm Single Stage Filter Assembly, 1/2" x 1" x 1/2" x 1", PFA clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$222.96
-
47 mm Two-Stage Filter Assembly, 1-1/2" x 1/4", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$256.83
-
47 mm Two-Stage Filter Assembly, 1-1/2' x 3/8", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$266.23
-
47 mm Two-Stage Filter Assembly, 1-1/2" x 1/4" MNPT, PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$263.52
-
47 mm Two-Stage Filter Assembly, 1/4" x 1/4", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$238.86
-
47 mm Two-Stage Filter Assembly, 1/4" MNPT x 1/4" MNPT, PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$245.81
-
47 mm Three-Stage Filter Assembly, 1-1/2" x 1/4", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$297.10
-
47 mm Three-Stage Filter Assembly, 1-1/2" x 3/8", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$304.88
-
47 mm Three-Stage Filter Assembly, 1-1/2" x 1/4" MNPT, PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$302.04
-
47 mm Three-Stage Filter Assembly, 1/4" x 1/4", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$293.60
-
47 mm Three-Stage Filter Assembly, 1/4" MNPT x 1/4" MNPT, PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$296.56
-
47 mm Four-Stage Filter Assembly, 1-1/2" x 1/4", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$339.19
-
47 mm Four-Stage Filter Assembly, 1-1/2" x 3/8", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$340.39
-
47 mm Four-Stage Filter Assembly, 1-1/2" x 1/4" MNPT, PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$349.83
-
47 mm Four-Stage Filter Assembly, 1/4" x 1/4", PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$331.84
-
47 mm Four-Stage Filter Assembly, 1/4" MNPT x 1/4" MNPT, PFA Clamp
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- All wetted components are molded PFA
- Filter membranes can be replaced without disconnecting lines
- PFA clamp nut for higher temperature applications
- Recommend wrench set for assembly
Material: PFA$335.02
-
Clamp, 47 mm Filter Single-Stage Filter, PFA, Orange
- Extended length for multiple stage filtration
- Clamp assembly molded of PFA
- Service temperature to 500°F (260°C)
- Orange color
- For use with 47 mm filter components
Material: PFA$53.68
-
Clamp, 50 mm Filter, PFA, Green
- Clamp assembly molded of PFA
- Service temperature to 500°F (260°C)
- Green color
- For use with 50 mm filter components
Material: PFA$54.79
-
Clamp, 25 mm Filter, PFA, Gray
- Clamp assembly molded of PFA
- Service temperature to 500°F (260°C)
- Gray color
- For use with 25 mm filter components
Material: PFA -
Clamp, 47 mm Multi-Stage Filter, PFA, Gray
- Clamp assembly molded of PFA
- Service temperature to 500°F (260°C)
- Gray color
- For use with 47 mm filter components
Material: PFA$69.40
-
PFA Beaker Lid, Vial Rack System
- Required if vial rack system is used with a 4 L glass beaker
- Slightly domed shape fits over rack system and covers the entire beaker
- Reduces liquid loss due to evaporation
Material: PFA$320.68
-
33 mm PFA Closure
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 260°C)
- Knurled finish on the closure
- Leakproof seal
Material: PFA$13.39
-
33 mm Impinger Closure, (2) 1/8" OD Tube Ports, PFA Insert, Ultem® Clamp
- Service temperature range of PFA is ‑370 °F to 500 °F (‑200 °C to 260 °C)
- Vertical port allows close assembly of sampling train
- Ultem® clamp for extra security
- Ultem® clamp does not contact contents
- Comes with closure listed in product description
- One port with tubing stop and one port for tube pass-thru
Material: PFA, PEI$113.93
-
33 mm PFA Impinger Closure, (2) 1/4" OD Tube Ports, One Top, One Side
- Service temperature range of PFA is ‑370 °F to 500 °F (‑200 °C to 260 °C)
- Side port with tubing stop and top port for tube pass-thru
- For use with 60 mL Impinger
Material: PFA$87.84
-
33 mm Impinger Closure, (2) 1/4" OD Tube Ports, PFA Insert, Ultem® Clamp
- Service Temperature Range to 275F
- Vertical port allows close assembly of sampling train
- One port with tubing stop and one port for tube pass-thru
- Ultem® clamp for extra security
- Ultem® clamp does not contact sample material
- For use with EPA and other air sampling protocols
Material: PFA, PEI$113.41
-
GL45 PFA Plain Threaded Closure
- Service temperature range of PFA is ‑328°F to 500°F (‑200°C to 200°C)
- Leakproof seal
- Fits Purillex bottles 100 mL – 2000 mL
- Torque adapter available (#730-0045)
Material: PFA$72.50
-
GL45 FEP Plain Threaded Closure
- Service temperature range of FEP is ‑328°F to 392°F (‑164°C to 200°C)
- Leakproof seal
- Fits Purillex bottles 100 mL – 2000 mL
- Torque adapter available (#730-0045)
Material: FEP$64.66